Hoshizaki KM-1301SRH/3 Ice Maker User Manual


 
45
3. KM-1301SWH (water-cooled)
Note:
1. Pressure data is recorded at 5 minutes into freezing cycle. The data not in bold
should be used for reference only.
. We reserve the right to make changes in specications and design without prior
notice.
70/21 1318 598 1319 599 1249 567
80/27 1319 598 1321 599 1211 549
90/32 1319 599 1323 600 1228 557
lbs./day kg./da
y
100/38 1281 581 1301 590 1141 518
70/21
80/27
90/32
watts 100/38
70/21 1407 5.33 1527 5.78 2049 7.76
80/27 1499 5.67 1686 6.38 2406 9.11
90/32 1527 5.78 1818 6.88 2465 9.33
gal./day m
3
/day
100/38 1861 7.04 1969 7.46 3060 11.58
70/21
80/27
90/32
min. 100/38
70/21
80/27
90/32
min. 100/38
70/21 235 16.5 236 16.6 246 17.3
80/27 236 16.6 237 16.7 253 17.8
90/32 236 16.6 238 16.7 252 17.7
PSIG kg/cm
2
G
100/38 241 16.9 241 17.0 264 18.6
70/21 50 3.5 50 3.5 52 3.6
80/27 50 3.5 49 3.5 52 3.7
90/32 50 3.5 49 3.4 52 3.6
PSIG kg/cm
2
G
100/38 51 3.6 50 3.5 54 3.8
17,600 BTU/h [AT 90ºF (32ºC) / WT 70ºF (21ºC)]
TOTAL HEAT OF REJECTION FROM COMPRESSOR 2,300 BTU/h [AT 90ºF (32ºC) / WT 70ºF (21ºC)]
WATER FLOW FOR CONDENSER 120 gal./h [AT 100ºF (38ºC) / WT 90ºF (32ºC)]
PRESSURE DROP OF COOLING WATER LINE less than 10 PSIG
31
31
32
2.4
4.5
3.2
3.9
3.1
31
33
APPROXIMATE ICE
PRODUCTION PER 24 HR.
APPROXIMATE ELECTRIC
CONSUMPTION
APPROXIMATE WATER
CONSUMPTION PER 24 HR.
FREEZING CYCLE TIME
WATER TEMP. (ºF/ºC)
AMBIENT TEMP.
(ºF/ºC)
50/10 70/21 90/32
1755
1746
1754
1760
1766
1740
1744
1746
33
34
34
36
1767
1782
1786
1810
31
32
32
HARVEST CYCLE TIME
3.5
3.0
3.9 2.22.4
4.0
2.1
TOTAL HEAT OF REJECTION FROM CONDENSER
SUCTION PRESSURE
HEAD PRESSURE
ENG.F-011.1.0205