6. KM-1301SRH3 (remote air-cooled)
Note:
1. Pressure data is recorded at 5 minutes into freezing cycle. The data not in bold
should be used for reference only.
. We reserve the right to make changes in specications and design without prior
notice.
70/21 1339 607 1297 589 1203 546
80/27 1307 593 1243 564 1127 511
90/32 1297 589 1197 543 1088 494
lbs./day kg./da
y
100/38 1266 574 1171 531 988 448
70/21
80/27
90/32
watts 100/38
70/21 463 1.75
384 1.45 338 1.28
80/27 403 1.52 279 1.06 269 1.02
90/32 384 1.45 192 0.72 165 0.63
gal./day m
3
/day
100/38 291 1.10 185 0.70 141 0.53
70/21
80/27
90/32
min. 100/38
70/21
80/27
90/32
min. 100/38
70/21 214 15.0
228 16.0 252 17.7
80/27 224 15.8 246 17.3 273 19.2
90/32 228 16.0 261 18.4 287 20.2
PSIG kg/cm
2
G
100/38 234 16.5 267 18.8 311 21.9
70/21 50 3.5 51 3.6 54 3.8
80/27 50 3.5 51 3.6 56 3.9
90/32 51 3.6 52 3.7 56 3.9
PSIG kg/cm
2
G
100/38 52 3.7 53 3.7 60 4.2
17,500 BTU/h [AT 90ºF (32ºC) / WT 70ºF (21ºC)]
2,400 BTU/h [AT 90ºF (32ºC) / WT 70ºF (21ºC)]
CONDENSER VOLUME 133 CU. IN (URC-14F)
32
32
34
2.2
3.9
2.9
3.4
2.8
2.2
3.5
31
APPROXIMATE ICE
PRODUCTION PER 24 HR.
APPROXIMATE ELECTRIC
CONSUMPTION
APPROXIMATE WATER
CONSUMPTION PER 24 HR.
FREEZING CYCLE TIME
WATER TEMP. (ºF/ºC)
AMBIENT TEMP.
(ºF/ºC)
50/10 70/21 90/32
2128
2105
2124
2140
2156
2090
2101
2105
35
37
39
42
2160
2199
2208
2270
36
32
33
35
2.1
SUCTION PRESSURE
HARVEST CYCLE TIME
HEAD PRESSURE
3.2
2.8
3.4 2.1
TOTAL HEAT OF REJECTION FROM CONDENSER
TOTAL HEAT OF REJECTION FROM COMPRESSOR
ENG.F-011.1.0205