47
Note:
1. Pressure data is recorded at 5 minutes into freezing cycle. The data not in bold
should be used for reference only.
. We reserve the right to make changes in specications and design without prior
notice.
5. KM-1301SRH (remote air-cooled)
70/21 1353 614 1315 596 1219 553
80/27 1324 600 1264 573 1144 519
90/32 1315 596 1222 554 1110 504
lbs./day kg./da
y
100/38 1281 581 1196 542 1008 457
70/21
80/27
90/32
watts 100/38
70/21 479 1.81
398 1.51 350 1.32
80/27 417 1.58 292 1.10 278 1.05
90/32 398 1.51 203 0.77 173 0.66
gal./day m
3
/day
100/38 303 1.15 196 0.74 146 0.55
70/21
80/27
90/32
min. 100/38
70/21
80/27
90/32
min. 100/38
70/21 211 14.8 226 15.9 246 17.3
80/27 222 15.6 246 17.3 265 18.7
90/32 226 15.9 262 18.4 282 19.9
PSIG kg/cm
2
G
100/38 230 16.2 267 18.8 301 21.2
70/21 50 3.5 51 3.6 53 3.8
80/27 50 3.5 51 3.6 55 3.9
90/32 51 3.6 52 3.7 56 3.9
PSIG kg/cm
2
G
100/38 52 3.6 53 3.7 59 4.1
17,600 BTU/h [AT 90ºF (32ºC) / WT 70ºF (21ºC)]
2,500 BTU/h [AT 90ºF (32ºC) / WT 70ºF (21ºC)]
CONDENSER VOLUME 133 CU. IN (URC-14F)
32
32
33
2.3
4.1
3.0
3.6
2.9
2.3
3.7
31
APPROXIMATE ICE
PRODUCTION PER 24 HR.
APPROXIMATE ELECTRIC
CONSUMPTION
APPROXIMATE WATER
CONSUMPTION PER 24 HR.
FREEZING CYCLE TIME
WATER TEMP. (ºF/ºC)
AMBIENT TEMP.
(ºF/ºC)
50/10 70/21 90/32
2052
2033
2064
2090
2105
2010
2028
2033
34
36
37
40
2088
2131
2153
2210
35
32
33
35
2.1
SUCTION PRESSURE
HARVEST CYCLE TIME
HEAD PRESSURE
3.3
2.9
3.6 2.2
TOTAL HEAT OF REJECTION FROM CONDENSER
TOTAL HEAT OF REJECTION FROM COMPRESSOR
ENG.F-011.1.0205