Hoshizaki KM-151BAH Ice Maker User Manual


 
13
H. Startup
CAUTION
1. All parts are factory-adjusted. Improper adjustments may result in failure.
2. If the unit is turned off, wait for at least 3 minutes before restarting the
icemaker to prevent damage to the Compressor.
* Check that shipping tape(s), string and packing are removed before starting the icemaker.
1) Open the Water Supply Line Shut-off Valve.
2) Remove the Air Filter.
3) Move the Control Switch on the Control Box to the “ICE” position.
4) Let the icemaker run for 10 minutes, then move the Control Switch to the “OFF”
position.
5) Open the Door.
6) Disconnect the Silicone Hose to drain the water. See Fig. 6.
7) Reconnect the Silicone Hose back in its correct position after all of the water has
drained.
8) Clean inside the Storage Bin and Door.
9) Move the Control Switch to the “ICE” position. This starts the automatic icemaking
process.
10) Close the Door.
11) Place the Air Filter in its
correct position.
Fig. 6
Cube Guide
Water Tank
Silicone Hose
(Connect/disconnect
arrowed part)
Overflow Pipe
(Disconnect from tank
bottom)
Storage Bin