5) Install the new fan motor in the reverse order of the removal procedure.
6) Re t the panels in their correct positions.
7) Plug in the icemaker or connect the power source.
Fig. 6
Fan Motor Bracket
Screw
Fan Motor
10. WATER REGULATING VALVE (WATER-COOLED MODEL)
CAUTION
1. Always install a new drier every time the sealed refrigeration system is
opened.
2. Do not replace the drier until after all other repair or replacement has
been made. Install the new drier with the arrow on the drier in the
direction of the refrigerant ow.
3. When brazing, protect the drier by using a wet cloth to prevent the drier
from overheating. Do not allow the drier to exceed 250°F (121°C).
1) Unplug the icemaker or disconnect the power source.
2) Remove the panels.
3) Close the condenser water supply line shut-off valve. If connected to a closed loop
water supply, also close the condenser return outlet shut-off valve.