3
(6) Shutdown
When MBC is activated (MBC open), the yellow "BC OPEN" LED comes on. The unit
then shuts down as outlined in the table below.
Cycle at
Mechanical Bin
Control Activation
Shutdown
Fill Cycle 5 seconds after activation.
Harvest Cycle At the end of the harvest cycle, or up to 5 seconds into the freeze cycle if activated
at the end of the harvest cycle.
Freeze Cycle 5 seconds after activation if activated at least 5 seconds before the 5-minute short
cycle protection timer expires. Otherwise, at the end of the next harvest cycle.
Legend: CB–control board; Comp–compressor; FM–fan motor;
FMR–fan motor-remote; F/S–oat switch; HGV–hot gas valve; LLV–liquid line
valve; MBC–mechanical bin control; PM–pump motor; WV–inlet water valve