Hoshizaki KM-901MAH Ice Maker User Manual


 
35
g) Freeze Timer (S4 dip switch 9 & 10)
CAUTION
Adjust to proper specication, or the unit may not operate correctly.
The freeze timer setting determines the maximum allowed freeze time to prevent
possible freeze-up issues. Upon termination of the freeze timer, the control board
initiates the harvest cycle. After  consecutive freeze timer terminations, the control
board shuts down the icemaker. In this case, see "IV.F.3. Low Ice Production" for
possible solutions. The freeze timer is factory set, and generally no adjustment
is required. Before changing this setting, contact Hoshizaki Technical Support at
-800-33-940 for recommendations.
S4 Dip Switch Setting
Time
(minutes)
No. 9 No. 10
OFF OFF 60
OFF ON 50
ON OFF 70
ON ON 60
h) Float Switch Control (S5 dip switch 1): "G" Control Board
CAUTION
Do not adjust. This must be left in the factory default position or the unit will not
operate correctly.
Factory set. S5 dip switch  allows for single or double oat switch applications. The
KM-90MAH, KM-90MWH, and KM-90MRH/3 use a single oat switch.
i) Refill Counter (S5 dip switch 2 through 5): "G" Control Board
CAUTION
Do not adjust. These must be left in the factory default position or the unit will
not operate correctly.
Factory set. S5 dip switch  through 5 allows for rells during the freeze cycle. The
KM-90MAH, KM90MWH, and KM-90MRH/3 do not rell.