Hoshizaki KM-901MAH Ice Maker User Manual


 
80
0) Secure the insulation using plastic cable ties.
) Connect the white thermistor connector through the bushing of the control box to the
control board WHITE K3 connector.
Note: Do not cut the leads of the thermistor.
) Replace the control box cover and the panels in their correct positions.
3) Turn on the power supply.
M. Removal and Replacement of Fan Motor (air-cooled and remote
air-cooled models)
Note: When replacing a fan motor with defective winding, it is recommended that a new
capacitor be installed.
) Turn off the power supply.
) Remove the panels.
3) Remote air-cooled model: remove the junction box cover from the remote condenser
unit.
4) Disconnect the fan motor wires.
5) Remove the fan motor bracket and fan motor.
6) Install the new fan motor, connect the fan motor wires, and replace the removed parts
in the reverse order of which they were removed.
7) Replace the panels in their correct positions.
8) Remote air-cooled model: replace the junction box cover in its correct position.
9) Turn on the power supply.
N. Removal and Replacement of Inlet Water Valve
) Turn off the power supply.
) Close the icemaker water supply line shut-off valve. Open the icemaker water supply
line drain valve.
3) Remove the front panel.
4) Disconnect the valve outlet tubing by releasing the clamp.
5) Loosen the tting nut. Be careful not to lose the washer.
6) Disconnect the terminals from the inlet water valve.
7) Remove the bracket and valve from the unit.
8) Install the new valve. Replace the removed parts in the reverse order of which they
were removed. Make sure the washer is in place in the tting nut.
9) Close the icemaker water supply line drain valve. Open the icemaker water supply line
shut-off valve.
0) Turn on the power supply.
) Check for leaks.