Electrical Connection
Warning - THIS APPLIANCE MUST BE EARTHED
The cooker must be connected by a qualified
electrician to a suitable double - pole control unit
with a minimum rating of 32A and a minimum
contact clearance of 3mm, which should be fitted
adjacent to (but not above) the cooker, in
accordance with IEE regulations.
The power supply cable should conform to BS6004
with a conductor size of 6mm
2
.
The control unit should be easily accessible in the
event of an emergency.
This appliance conforms to EN55014 regarding
suppression of radio and television interference.
Access to the cooker terminals is by un-clipping the
cover. The mains cable must pass through the cable
clamp and the screws must be fully tightened.
Sufficient cable should be used to allow the cooker
to be pulled out for servicing. Ensure that the cover
is fully closed and secure afterwards.
Take care not to trap the mains cable when pushing
the cooker into its final position.
Operational Checks
After installation, check for gas soundness. The
supply pressure can be checked at one of the
hotplate burner injectors.
Check that the hotplate burners ignite correctly
and burn with a steady flame.
Check for a steady flame at the low setting.
Instruct the user on the operation of the cooker.
WARNING – THIS APPLIANCE MUST BEWARNING – THIS APPLIANCE MUST BE
WARNING – THIS APPLIANCE MUST BEWARNING – THIS APPLIANCE MUST BE
WARNING – THIS APPLIANCE MUST BE
EARTHED.EARTHED.
EARTHED.EARTHED.
EARTHED.
Electrical connection
Electric cookers come without a power supply cable.
The cooker is designed to operate on an electricity
supply which conforms to the electrical data shown
on the Rating Plate. The cooker can be connected to
the mains only after removing the back panel of the
cooker itself with a screwdriver.
N.B.:N.B.:
N.B.:N.B.:
N.B.: the following installation procedure must be
carried out by a qualified electrician. The electrical
installation must comply with the IEE Regulations,
Building & local By-Lays.
For the installation of the feeding cable carry out the
following operations:
1 Open the terminal
board by inserting a
screwdriver into the
side tabs of the cover.
Use the screwdriver as
a lever by pushing it
down to open the cover
(see diagram).
2 Loosen the cable
clamp screw and
remove it, using a
screwdriver as a lever
(see figure).
3 Remove the wire
contact screws L-N-
,
then fasten the wires
under the screw heads,
respecting the colour
code: Black/Blue (N),
Red/Brown (L) and Bare Wire/Yellow-Green (
)
l Once the connections have been made, tighten
all the terminal screws fully.
l Fasten the supply cable in place with the clamp
and close the cover of the terminal board.