Hotpoint Oven Microwave Oven User Manual


 
i) When installed in a typical
600mm deep built in housing unit,
the false back should be removed
from the housing unit to provide the
necessary depth for installation.
ii) When the false back is removed, it
is normally the case that the support
shelf for the appliance leaves a
gap between the back edge and
the wall of approximately 80mm.
iii) If no gap occurs between the back
edge of the shelf and the wall
behind the unit, we recommend
that a gap of at least 30mm is
made by shortening the shelf.
iv) When installing the appliance
below a worktop, there must be a
minimum ventilation area of 60cm
2
below the appliance, in either
area (1) or (2), as indicated below.
There must be a 5mm gap
between the front top edge of the
oven and the underside of the
worktop.
Important: Do not modify the outer
panels of this appliance in any way.
Ensure that you route all mains
electrical cables and flexible tubing
well clear of any adjacent heat source,
such as an oven, grill or hob.
Ensure that all pipe work is of the
correct rating for both size and
temperature.
Installing the appliance under a
worktop
Where the appliance is installed under
a worktop, with a hob installed above
it, the installation instructions for the
hob must be read in conjunction with
these instructions.
23
worktop
support shelf
front
of oven
5 mm
30 - 80
mm
minimum
ventilation
area 60 cm
2
(1)
(2)
Installation Instructions
08 27250 00 - Creda SC11 9/5/05 3:32 PM Page 25