CONVERTING TO LP GAS (Sealed Burner models only)
or Converting Back to Natural Gas from LP
Orifice Spuds for Converting to LP Gas:
LP orifice spuds are in a small plastic bag packed
with this Use and Care Guide or on a bracket
next to the pressure regulator. LP orifice spuds
have a 2-digit number and the letter “L” on top.
Each orifice spud will also have 1, 2 or 3 grooves
on the top, and some will have a painted side,
denoting the location on the range where it is to
be installed as shown below.
L
L
L
L
A
Orifice Spuds for Converting to Natural Gas:
Natural gas orifice spuds have a 3-digit number
and the letter “N” on the top. Each orifice spud
will also have 1, 2 or 3 grooves on top denoting
the location on the range where it is to be
installed as shown below.
N
N
N
N
B
CONVERTING SURFACE BURNERS
1. Remove grates, burner caps and burner heads.
2. Remove the brass orifice
spud inside the chimney of
each burner using a 9/32″
or 7 mm nut driver.
3. Install the orifice spuds
according to one of the
following diagrams (see
or ), for LP gas or
natural gas, depending on
which you are converting to.
B
A
3
Front of Range
Front of Range
(continued next page)
Electrode
Drip Pan
(on some models)
Grate
Burner Head
Burner Cap
Orifice spud
Chimney
White
Brown
Brass
Brass
I
III
II
II