hussman MAXI-140 Freezer User Manual


 
Condenser Coil
To maintain peak operating efficiency, use a
soft hand brush or soft brush attachment on a
vacuum to remove accumulated dust from the
coil at least once each month. A dirty coil will
slow product cooling significantly and can
increase energy consumption by as much as
20%. Consult an authorized technician if more
extensive cleaning is needed.
LAMP REPLACEMENT
Fluorescent (Canopy Display Lighting)
Fluorescent lamps must be replaced by lamps
of the same size dimension and wattage as the
original. Always unplug unit before replacing
lamp. Restocked beer may freeze.
1. Sell all product in the unit.
2. Turn off lamp switch. Unplug the unit.
3. Remove shelves.
4. Remove the two recessed screws from the
canopy. Screws are accessible through holes in
the bottom of the canopy cover.
5. Carefully remove the bottom canopy edge
from the unit.
6. Disconnect blue temperature display
connector from the canopy.
7. Carefully remove the canopy and set aside.
©2007 HUSSMANN CORPORATION • BRIDGETON, MO 63044-2483 U.S.A.
U.S. & CANADA 1-800-504-4828 • WWW.CHILLCHAMBER.HUSSMANN.COM
12
P/N 31033596_B
01 June 2007
MAXI-140
Recessed access
Aftermarket Part # Description
BU.4440801 T5 8W (Interior Lamp)
BU.4481682 LED
Temperature display connector
Bottom canopy edge