Water Supply and Drain Connection:
1. The recommend water supply line is ¼ inch O.D. copper tubing. The minimum incoming water
pressure should be 20 psig.
2. Connect the water supply tubing to the water inlet fitting (3/4 hose thread) at the rear of the
icemaker. An optional adapter (1/4 compression x ¾ hose thread) is available under part
number 1011337-43, or from a local hardware store
3. Install a water shutoff valve on the incoming water line near the icemaker so that the water can
be shut off for service.
4. Connect a gravity drain line to the drain connection at the icemaker. A minimum slope of ¼
inch fall per foot of horizontal run is recommended. Install the drains per local code. A vent is
recommended on the highest point of the drain tube, and the drain tubing must be rigid pipe.
DO NOT use flexible tubing.
Electrical
1. Locate the nameplate on the lower rear panel and check that the location source voltage and
capacity are correct for this unit. The unit is supplied with a grounded plug connection.
2. Under no circumstances must the ground post be altered or removed.
3. Be certain that the icemaker is connected to its own electrical circuit and is individually fused.
4. The maximum allowable voltage variation should not exceed ten percent of the name plate
rating.
5. All external wiring should conform to the National, State, and local electrical code requirements.
Usually an electrical permit and the services of a licensed electrician will be required to install
the receptacle.