Cornelius 000 PLUS Refrigerator User Manual


 
12300614000
Low-Calorie (diet) Syrup Soft Drink Tank CO
2
Regulator.
Adjust low-calorie (diet) soft drink tank secondary CO
2
regulator for low-calorie drink at 10-psig for
syrup lines up to 30-feet in length. Syrup lines longer than 30-feet in length may require a slightly higher
CO
2
regulator setting to 12-psig maximum. Excessive CO
2
pressure may cause low-calorie syrup
carbonation resulting in foam.
IMPORTANT: Syrup systems must be sanitized as instructed before syrup is connected into syrup
systems.
11. Connect soft drink tanks into syrup systems.
12. Dispense from dispensing station dispensing valves until product is dispensed.
LEAK CHECK AND INSULATING COOLING UNIT OUTLET LINES
1. Check all CO
2
, plain and carbonated water, and syrup connections for leaks and repair if evident.
2. Make sure Cooling Unit outlet lines connections to insulated python lines are well insulated.
3. Install Cooling Unit top cover and secure with two screws.
DISPENSING STATION ADJUSTMENTS
ADJUSTING WATER FLOW RATE
Refer to Installation Instructions provided with Dispensing Station for dispensing valve water flow rate
adjustment instructions.
ADJUSTING WATER-TO-SYRUP ‘ ‘RATIO’’ OF DISPENSED PRODUCT
Adjust Dispensing Station dispensing valves for Water-to-Syrup ‘‘Ratio’’ of dispensed product as instructed in
dispensing station Installation Instructions.
INSTALLING LINE IDENTIFICATION LABEL
Install LABEL, LINE IDENTIFICATION (item 4) on Cooling Unit and record syrup flavors in proper spaces.