Cornelius ICE FROST Blender User Manual


 
Ice Frost Operator’s Manual
© 2004-2006, IMI Cornelius Inc. - 25 - Publication Number: M620919596OPR
TROUBLESHOOTING
NOTE: The following procedures must be performed by a qualified service technician.
Problem Possible Cause Solution
“Filt” or “Err” message appears on
the touchpad LED readout
The filter is dirty and needs to
be cleaned
The unit is positioned too close
to a wall or other object restrict-
ing air flow and causing the
machine to run at a higher tem-
perature
The filter is not properly
installed
The unit has been installed
near a heat source, such as a
coffee machine, ice maker or
cold beverage machine which
expels hot air from its vents,
causing the machine to run at a
high temperature. (Installation
near a heat source should be
avoid)
Clean and replace filter follow-
ing instructions (Removing and
Cleaning Filter)
Reposition unit to maximize
ventilation space (see installa-
tion figures)
Properly install filter see
“Removing and cleaning filter”
Reposition unit to maximize
ventilation space (see installa-
tion figures)
The machine does not cool, or
cools only partially, but the com-
pressors are running
The space around the machine
is inadequate for ventilation
Freezer is in COLD mode
The condenser fins are clogged
with airborne particles
Fan motor is not running
Refrigerant is low
Allow at least 8” (20cm)
between the machine and any-
thing next to it; keep away from
heat sources
Return to FROZEN mode
Remove the side panels. Using
a brush or compressed air
clean the condenser
Check the fan motor’s electrical
connections and, if discon-
nected, reconnect. If still not
operating, replace the motor
Locate the leak, eliminate it and
recharge the system
The machine does not cool or
cools only partially, but one or
more of the compressors are not
running
Defective Electrical components
Loose wire connections
One or more of the compressors
are malfunctioning
No current is coming to the
“compressor delay” PC board
Replace the malfunctioning compo-
nents
Check the contacts and correct
those that are incomplete
Replace the compressor(s)
Check the electrical connections to
the PC board as well as the trans-
former feeding the PC board and
correct