Problem Possible Cause Solution
The machine over-freezes making
the auger movement slow or
stopped
The product Brix/ratio is too low
The screw setting for the product
consistency control system is set
too far toward the “+” position
The limit switch arm is bent away
from the gearmotor and prevents
contact
The level of the product in the bowl
is too low, exposing the auger
The compressor PC board contacts
don’t open
Check the product Brix/ratio and
correct
Reset the screw toward the “-”
position to produce a thinner con-
sistency product
Using pliers, straighten the limit
switch
arm
Add more product or turn the refrig-
eration “Off”
Replace the PC board
The machine is noisy The fan motor blades are hitting
internal components
• Check and correct
The main power switch is “On”.
The unit is not running.
The fuse(s) are blown
The pressure cutout switch has
activated
Some electrical connections are
not complete
The main power is not functioning
Replace the fuse(s)
Clean the condenser or add venti-
lation space around the machine
(the cutout switch reset is auto-
matic when the conditions are cor-
rected)
Check the contacts and correct
those that are incomplete
Replace the switch
Product is leaking out of the bowl One of the bowl seals is not in
place
Replace or reposition the seals
Product is leaking from the dis-
pensing valve
The dispensing valve has been
incompletely or incorrectly replaced
in its position
The free movement of the dispens-
ing valve is impeded
Dispensing valve o-rings are dam-
aged
Reassemble and replace
Clean and lubricate the valve and
valve cylinder with the lubricant
provided with the machine
Replace the o-rings
Product is flowing into drain tray
through drainage tube
The bell shaped “shaft” seal
between the front of the cylinder
and the auger hub has not been
reinstalled properly
The bell shaped “shaft” seal or the
spindle bushing seal is damaged or
worn
Find the seal and put it back in
place
Replace the damaged/worn seal
and check the condition of the
driveshaft.
The auger is not turning Auger not turned on
Some electrical connections are
not complete
The gear motor(s) are malfunction-
ing
Turn auger on
Check the contacts and correct the
ones that are incomplete
Replace the gear motor(s)
The auger is creating noises as it
rotates
The large red bowl seal is not in
position, causing the gear teeth not
to mesh
The product brix is incorrect
The bell shaped “shaft” seal has
been replaced without lubrication
or is damaged
The auger has been incompletely
or incorrectly reassembled (ie the
auger’s gear pins are not properly
seated)
Check and correct
Check the product brix and correct
Replace or Clean and lubricate
with the lubricant provided with the
machine
Check and correct