Cornelius UC 701 Ice Maker User Manual


 
12
630460150
SemiAnnually
Semi-Annually in addition to all previously established service procedures perform the following:
1. Check for water leaks in tube connections, water fittings and lower Icemaker water seal.
2. Check drain tubes for clogs and aged tubes. Replace if tubes are stained or brittle.
3. Check for signs of condensation. Clean where necessary and replace insulation properly.
4. Check safety circuits for proper operation.
5. Check refrigeration system (see page 13).
6. Check unit for abnormal noise. Tighten machine and cabinet screws, if necessary.
7. Check white upper bearings on auger assembly. If bearings are less than 1/16Ȃ thick, replace. See Figure 4
REPLACE
OK
REPLACE
1/16Ȃ
OK
1/16Ȃ
FIGURE 4. UPPER NUT AND BEARING ASSEMBLY
WATER LEVEL CONTROL
How Water Level Control Works
When water is introduced through the inlet fitting the float rises. the float pushes against a lever which in turn
forces the poppet assembly against the inlet fitting valve seat which seals the water off. See Figure 3 Before the
water inlet is sealed the safety switch is operated. In the event of a water failure the float would drop down and
operate the safety switch to shut off the machine.
If water level control will not shut off and seal at level as indicated, be sure inlet pressure does not exceed rec-
ommended factory operating range.
Under ordinary circumstances adjustment should not be necessary providing it was properly adjusted when unit
was installed or relocated. If, however, the control becomes inoperative, repair or replace. See Start-Up Adjust-
ment, page 9.
Purpose
1. To automatically maintain proper water level in the evaporator when unit is running and making ice.
2. A safety switch is operated in the event of an interruption in water supply. The switch shuts off the electrical
power to the icemaker and its refrigeration system. Switch will reset as soon as cause of water failure has
been corrected and proper water level in icemaker has again been reached.