Cornelius UC 701 Ice Maker User Manual


 
13
630460150
3. The transparent bowl not only provides a visible check of water level, but also is a good guide to the inter-
nal conditions which exist within the icemaker assembly itself. (See Cleaning Procedure.)
To Replace Water Level Control
1. Shut off the water supply. Shut off the main power switch or unplug the ice dispenser from electrical outlet.
2. Remove the flexible tubing from bottom of water level control and drain water from water level control and
evaporator.
3. Remove flexible tubing at bottom of water level bowl connected to the overflow.
4. Hold water inlet fitting with proper tool to prevent it from rotating when disconnecting the water inlet.
5. Remove wing nut holding water control to its mounting bracket. Control can be removed by lifting straight
up.
To Replace Water Level Safety Switch
1. Shut off main power switch or unplug the ice dispenser from electrical outlet.
2. Unplug molex connector connecting switch to electrical box.
3. Remove the 2 screws anchoring the water level safety switch to the bottom of the water level control
mounting bracket.
REFRIGERATION SYSTEM
NOTE: Thermostatic Expansion Valve No Adjustment
+10 Lbs Discharge Pressure
WATER TEMPERATURE
A 40° 65° 90°
I 50° 174 177 180
R 60° 202 205 208
70° 230 233 236
T 80° 265 269 272
E 90° 300 304 307
M 100° 328 334 340
P
REFRIGERATION SYSTEM ADJUSTMENTS
A complete understanding of the icemaker and hermetic refrigeration system is necessary before any adjust-
ments are made. The refrigeration technician must use high and low side pressure readings, water and air tem-
peratures, plus general conditions of cleanliness to assess the refrigeration system status when making any
adjustments.
All icemaker products are tested and adjusted at the factory prior to shipment where the ambient temperature
ranges from 65_ to 90_F, depending on the season of the year.
Whenever a new icemaker product is initially installed and started-up, it is imperative that the start-up operation
make the following checks and/or readjustments for local conditions.