Table 1. Design Data (cont’d)
Water Supply–Water inlet fitting is 1/4–inch SAE flare located at the top front of the Unit. The Unit is designed
to operate on water pressure between 10 PSI and 90 PSI.
Drain Overflow Line (Located at rear of the Unit) 3/8–inch Flexible Tubing
Ambient Operating Temperature 40° F to 100° F
Electrical:
Unit Electrical Rating 208/230 VAC, 60 Hz, 11.3 Amps,
Single Phase
Recommended Electrical Supply 208/230 VAC, 60 hz, 20 Amps
Dedicated 3–Wire
Grounded Circuit
SPECIFICATION CHART
Models Condensing
Uit
VAC HZ PH Wire Comp.
RLA
Fan
A
GRMTR
A
Refrigerant
Circuit
F
g
Unit RLA Amps Amps
Oz. Type
Fuse
UC701–A Air Cooled 208/230 60 1 2 7.7 1.6 2 13 R404A 20
UC701–W Water Cooled 208/230 60 1 2 7.7 N/A 2 13 R404A 20
650
600
550
500
450
400
350
Capacity Lbs./24 hr.
Capacity Lbs./24 hr.
90 80 70 60 50
Water Temperature Deg. F
Air Temperature Deg. F
–50 –70 –90 –100
UC700