ELECTRICAL POWER CONNECTION:
Electrical and grounding connections must comply with the applicable portions of the National
Electrical Code ANSI/NFPA 70 (latest edition) and/or other electrical codes.
Disconnect electrical power supply and place a tag at the disconnect switch to indicate that you are working on the circuit.
The dishmachine data plate is located on the front of the machine. Refer to the data plate for machine operating requirements, machine
voltage, total amperage load and serial number.
To install the incoming power lines, remove the kick panel. This will require taking a phillips head screwdriver and removing the two (2)
1/4 turn screws at the bottom of the kickplate; open the door slightly while carefully lifting the kickplate up and out of the way. Install
3/4” conduit into the pre-punched holes in the back of the control box. Route power wires and connect to power block and grounding
lug. Install the service wires (L1 and L2) to the appropriate terminals as they are marked on the terminal block. Install the grounding
wire into the lug provided. It is recommended that “DE-OX” or another similar anti-oxidation agent be used on all power connections.
VOLTAGE CHECK: Ensure that the power switch is in the OFF position and apply power to the dishmachine. Check the incoming
power at the terminal block and ensure it corresponds to the voltage listed on the data plate. If not, contact a qualified service agency
to examine the problem. Do not run the dishmachine if the voltage is too high or too low. Shut off the service breaker and mark it as
being for the dishmachine. Advise all proper personnel of any problems and of the location of the service breaker. Replace the control
box cover and tighten down the screws.
INSTALLATION INSTRUCTIONS (CONTINUED)
3