InstallationOf Appliance
Followaccompanying ducting instructionscarefully. NOTE: For some cabinet styles, it may be necessary to
reinforce the front of the cabinet by attaching a brace
This appliance is designed to always be vented outdoors, from front to rear inside the cabinet under the Burner Box.
The Countertop Cutout, Cabinet Front Cutout and Duct Installductwork perducting instructions provided. Duct
Opening should be prepared according to the illustration openings in cabinet are shown in the drawing on page 1.
on pages 1 and 2. Make electricaland gas connections as described below
Installthe Lower Control Panelin the bottom of the in this section of the instructions.
Cabinet Cutout as shownusing screwsfrom Hardware The installationof thisappliance must conformwithlocal
pack. (Figure 1). codesor,inthe absenceof localcodes,with the latest
editionofthe NationalFuelGas Code, ANSI Z.223.1 USA
Tl_pVlml LOWER_ PANEL
or current CAN/CGA-B149 INSTALLATION CODE.
The electrical supply required is 110/120--volt,A.C., 15
amp, 60 Hz.This appliance is equipped with a grounded
type power cord. A grounded outlet must be provided. It is
recommended, for convenience, this outlet be located in
Figure 1 L. I _=,,_l II LF the areashown in the shaded illustration. This appliance,
when installed, must be electrically grounded in
accordance with local codes or, in the absence of local
codes, with the latest edition of the National Electrical
Position unitinthe Countertop Cutout. Main Control Panel Code ANSI/NFPA No. 70 USA or current CSA
should overlaptop of Lower Control Panel as shown. STANDARD C22.1 Canadian Electrical Code part 1.
(F{gure 2).
¢¢®e e,,-= ¢ ®
.EL Servicing Cooktop
When servicing cooktop it is necessary to remove the
F_gure2 main top, prior to removing the control panel.