TO CONVERTAPPLIANCEFORUSEWITHNATURALGAS
PropaneGas(LP)To NaturalGas Model- JGD8348BDP
ConversionInstructions Manifold- Natural Gas pressure required - 5" W.C.
If this appliance has beenconverted for usewith LP Gas, Incoming Natural Gas pressure required to appliance
each of the following modifications must be performed to pressure regulator - 6" - 7" W.C.
convert the unit back to Natural Gas.
Natural Gas input specified - 56,000 BTU/hr.
A. Replace allorifice hoods - Perform steps 1through 4on
page7.Locate the (6)sixNaturalGas hoods (withsmall
numbersstamped ontheir sides savedfrom theoriginal
Natural Gas unit). Page 5 Illustration "E'. The two
hoods with .0520 (#55 orifice) stamped on them are for
the left front and left rear burners. The four hoods with
the .0595 (#53 orifice) stamped on them are for the two
right burners.
To make these conversion adjustments follow the
instructions and illustrations ("A" through "E") pages
5-7.
B. Invert cap in appliance pressure regulator (see
Illustration "D", page 6). With the appliance installed,
the appliance pressure regulator is located on the right
underside of the appliance at the inlet to the gas
manifold. Identify the type of appliance pressure
regulator on the unit and follow the instructions in the
appropriate illustration.
C. Adjust low flame setting for each burner. Follow the
instructions for burner lowflame adjustment on page 7
to increase the simmer flame size.
Q
Q
JGD8348BDP
Left Rear (LR) 8,000 #55 .0520 Green
Left Front (LF) 8,000 #55 .0520 Green
Center Rear (CR) 10,000 #53 .0595 Brass
Center Front (CF) 10,000 #53 .0595 Brass
Right Rear (RR) 10,000 #53 .0595 Brass
Right Front (RF) 10,000 #53 .0595 Brass
9