Conversion To LP Gas Control Settings
This appliance isshipped from the factory equipped for The size andtypeof cookwareand theamountand type
usewithNaturalGas. To convertit from NaturalGas for of foodbeingcookedwillinfluencethe settingneededfor
usewithLP Gas, performsteps1 through4. bestcookingresults.The settingindicatedshouldserve as
1. Remove NaturalGas orificehoods.Installcolorcoded a guidewhileyoubecomefamiliarwith yourcooktop.
orificehoodssupplied.Locatedina packattachedto
theouterplenumarea ofthisappliance, UsetheHI flame settingto
quicklybringfoodstoa boilor to
(See Illustration"E", below,and LP Gas Conversion begina cookingoperation.Then
instructionspage 8). reducetoa lowersettingto
2. _nvertcap inconvertiblepressureregulator(ifso continuecooking.Never lease
equipped)locatedat entrancetogasmanifold, foodunattendedovera HI flame
3. Adjustair shutterson individualburnersforproper setting.
flameappearance.
Med settingisusedtocontinuea
4. Adjustlowflame settingat each burnerbyturning cookingoperation.Foodwillnot
adjustmentscrew incenter ofvalvestem. cookanyfasterwhen a HI flame
To make theseconversionsadjustmentsfollowthe settingisusedthanthatneeded
instructionsand illustrations("A"through"E",pages tomaintaina gentleboil.
5-7). Remember,water boilsat the
same temperaturewhetherboiling
gentlyorvigorously.
Applya non-corrosiveleak detectionfluidtoalljoints Use LO settingtokeepfoodat
andfittingsinthe gasconnectionbetweenthesupply servingtemperatureswithout
lineshut-offvalveand the range. Includegasfitting furthercookingYou mayfindthat
andjointsin therangeifconnectionswere disturbed somecookingmay take placeif
duringinstallation.Checkforleaks!Bubblesappearing the cookwareiscovered.
aroundfittingsand connectionswillindicatea leak, Ifa
leak appears,turnoffsupplylinegas shut-offvalve,
tightenconnections,turnonthe supplylinegasshut
offvalve,and retestfor leaks.Nevertestforgas leaks
withan openflame.
This appliance isshipped from the factory with orifice
hoods drilled for usewith Natural Gas. To convert from
Natural Gas to LP, apply a 112"open-end wrench to hex
section of orifice hood. Turn counterclockwise to remove.
Save the Natural Gas orifice hoodsjust removed from this
appliance for future use. Install color coded orificehoods
supplied. (See LP Gas Conversion instructions above and
page 8). Turn clockwise to install. Holddimension
specified in illustration "E".
1/2" OPEN END _ J
WRENCH
_ TURN
CLOCKWISE
• TO TIGHTEN
TURN
1
COUNTERCLOCKWISE
TO REMOVE ORIFICE HOOD
Illustration "E"