Jenn-Air SIDE- BY- SIDE REFRIGERATOR Refrigerator User Manual


 
32
No indicator lights
are lit on dispenser
control
Ice or water are
not dispensed
when pads are
pressed
Ice maker is not
producing enough
ice or ice is
malformed
Ice f
orms in inlet
tube to ice maker
Refrigerator is
leaking w
ater
Verify that freezer door is closed. Power is removed
from the control when freezer door is opened.
P
lug in refrigerator.
Replace any blown fuses.
Check circuit breakers for any tripped circuits.
Call local power company listing to report outage.
See
Sabbath Mode, page 18.
Verify that freezer door is closed. Power is removed
from the control when freezer door is opened.
See Dispenser LOCK, page 18.
At initial use, there is an approximate one- to two-
minute delay in dispensing while the internal water
t
ank is filling.
Reinstall ice bin, see page 16.
Wait 24 hours for ice production to begin or for ice
maker to restock after emptied.
Water pressure must be between 35 to 100 pounds
per square inch to function properly.
A minimum pressure of 35 pounds per square inch is
recommended for refrigerators with water filters.
Change water filter (see page 19).
Wait 24 hours for ice production to begin or for ice
maker to restock after emptied.
Low water pressure can cause valve to leak.
Water pressure must be between 35 to 100 pounds
per square inch to function properly. A minimum
pressure of 35 pounds per square inch is
recommended for refrigerators with water filters.
Change water filter
(see page 19).
Water pressure must be between 35 to 100 pounds
per square inch to function properly
.
A minimum pressure of 35 pounds per square inch is
recommended for refrigerators with water filters.
Open saddle valve completely.
See
T
emperature Controls,
page
s 9-11. F
reezer
temperature should be between 0° to 2° F (-18° to
-17
°
C).
T
he manufacturer recommends using copper tubing
for installation. Plastic is less durable and can cause
leakage. T
he manuf
actur
er is not responsible for
property damage due to improper installation or
water connection.
See Connecting the W
ater Supply
,
page
s 6 and 7
.
Self-piercing and
3
16” saddle valves cause low water
pressure and may clog the line over time.
The
manufacturer is not responsible for property
damage due to impr
oper installation or w
ater
connection.
Freezer door is not closed.
R
efrigerator is not plugged in.
Fuse is blown, or circuit breaker needs to
be reset.
Power outage has occurred.
Refrigerator is in Sabbath Mode (select
models).
Freezer door is not closed.
Controls are in lock mode (select models).
Water tank is filling.
Ice bin not installed properly.
Ice maker has just been installed or a
large amount of ice has been used.
Water pressure is to low.
Water filter is clogged or needs to be
changed.
Ice maker has just been installed or a
large amount of ice has been used.
Water pressure is too low.
Water filter is clogged or needs to be
changed.
Water pressure is too low.
Saddle valve not open completely.
Freezer temperature is too high.
Plastic tubing was used to complete
water connection.
Improper water valve was installed.
PROBLEM
POSSIBLE CAUSES WHAT TO DO
Ice and Water
TROUBLESHOOTING