Kenmore 795-71022.010 Refrigerator User Manual


 
- 27 -
8-3 Icing Sensor Error (Er IS)
No
1
2
Checking flow
Check for a loose connection.
Check the Blue to Blue.
Result & SVC Action
<Temperature table-1>
(1) To (2)
-22°F / -30°C
-13°F / -25°C
-4°F / -20°C
5°F / -15°C
14°F / -10°C
23°F / -5°C
32°F / 0°C
Result
40
30
23
17
13
10
8
The sensor is determined by
the temperature.
For example, 23
indicates -4°F.
<CON101>
<Display>
<CON101>
0
Infinite
ohms
See
resistance
table
Short
Open
Normal
Change the sensor
Check the resistance
of the defrost sensor
wires back to the
main PCB. If they are
open between the
Main PCB and the
connector for the
icemaker it will be
necessary to replace
the refrigerator.
Check the Temp and
resistance (Table-1)
Result SVC Action