Kenmore DP840DWG Dishwasher User Manual


 
5
4. Disconnect the drain hose from the drain valve by loosening the Hex-head screw on the hose
clamp. (Fig. 1-7)
5. Disconnect the pump inlet hose from the pump and motor assembly. (Fig. 1-7)
6. Remove the pump and motor assembly from the bottom of the dishwasher.
Fig. 1-7
PUMP INLET
HOSE
DRAIN
HOSE
NOTE: Once the pump and mo-
tor assembly has been
removed from the tub,
the pump outlet grom-
met can be removed
from the inside of the
tub. Check the pump
outlet grommet for wear
or damage and replace
it if necessary.
The motor can be removed from the pump assembly by removing the three T-20 Torx screws securing
the motor to the pump assembly.
(Fig. 1-8)
TORX
SCREWS
NOTE: When reinstalling the
motor make sure the
keyed motor shaft lines
up with the pump impel-
ler.
Fig. 1-8
Servicing the Pump Assembly
The pump impeller can be accessed by using
an adjustable slip-nut wrench to turn the
disk mount assembly counterclockwise.
Once the disk mount assembly is removed,
the impeller can be removed.
(Fig. 1-9)
The drain valve can be accessed by removing
the four (4) T-20 Torx screws securing the drain
outlet cover to the pump assembly. The drain
cover seal, diaphragm and diaphragm ring can
be removed and replaced.
(Fig. 1-10)
TORX
SCREWS
SLIP-NUT WRENCH
Fig. 1-9
Fig. 1-10