5-4
TEMPERATURE SENSOR
Refer to page 4-10 for the procedure for servic-
ing the heater element assembly. NOTE: The
temperature sensor is part of the heater ele-
ment assembly.
1. Unplug dishwasher or disconnect power.
2. Disconnect the wire connector from the
CHASSIS HARNESS terminals on the
controller.
3. Set the ohmmeter to the R x 1 scale.
4. Touch the ohmmeter test leads to heater
terminals 1 and 2. The meter should indi-
cate as follows:
962 Ω @ 68°F (20°C)
1000 Ω @ 86°F (30°C)
1200 Ω @ 140°F (60°C)
1
2
WATER FILL VALVES
Refer to page 4-16 for the procedure for servic-
ing the water fill valves.
1. Unplug dishwasher or disconnect power.
2. Disconnect the wire connectors from the
water fill valve solenoid terminals.
3. Set the ohmmeter to the R x 1 scale.
4. Touch the ohmmeter test leads to the up-
per and lower water fill valve solenoid
terminals. The meter should indicate be-
tween 65 and 75 Ω.
Solenoid
Terminals
WARNING
Electrical Shock Hazard
Disconnect power before servicing.
Replace all parts and panels before operating.
Failure to do so can result in death or electrical shock.
Upper
Lower