PREPARING THE LOCATION
Access holes in the cabmets, floor, or rear wall for the hot water supply line, drain line, and electrical supply must
be located within the shaded area in Fig. 3 in order to avoid Interference with the dishwasher frame or other
components.
HOT WATER SUPPLY LINE
Fig. 3
PLUMBING CONNECTIONS MUST COMPLY WITH APPLICABLE SANITARY, SAFETY, AND PLUMBING
CODES.
I
Water supply should be 120°F (49OC) minimum at the dishwasher. (Refer to Use & Care Guide.)
The hot water supply line should be 5%” (16 mm) OD copper tubing or
l/2”
(13 mm) galvanized pipe. The
dishwasher fill valve has a l/z” (13 mm) NPT female connection.
Atter determining where the water supply line will enter the dishwasher opening, drill a 1” (25 mm) access
hole and run the line to the approximate fill valve location as shown in Fig. 4.
4” (102 mm)
- (Frbm floor)
6” (152 mm)
Fig. 4
For service convenience, a shut-off valve (not supplied) should be installed in the supply line in a readily accessible
location (such as beneath the sink) and a union (not supplied) should be installed in the supply line near the
dishwasher fill valve.