KitchenAid Ventilation Hood Ventilation Hood User Manual


 
Range Hood Care
Range Hood Lamps
The range hood uses 12-volt 20-watt halogen lamps. Before you
begin, make sure that the range hood is turned off and that the
other lamps have had sufficient time to cool.
Replace lamp using a tissue to handle the lamp or wear cotton
gloves. Do not touch the lamp with bare fingers.
If new lights do not operate, make sure the lamps are inserted
correctly before calling service.
To Replace:
1. Turn light switch to off.
2. Disconnect power.
3. Gently pull the lamp from the socket clips.
4. Insert the new lamp into the socket clips and gently push the
lamp until firmly in place.
5. Reconnect power
Replacing Hood Lamps Fuse
If all the lights do not light when the light switch is turned on,
check that the fuse is good.
1. Disconnect power at the circuit breaker of fused circuit box.
2. Locate the fuse holder assembly next to the terminal box.
3. Remove the 2 screws from the cover.
4. Pull the cover back to gain access to the fuse holder.
A. Terminal box
B. Fuse holder assembly
C. Screws
A
B
C
A. Fuse cover
B. Fuse
C. Fuse holder
A
B
C
10
Range Hood Use
The range hood is designed to remove smoke, cooking vapors
and odors from the cooktop area. For best results, start the hood
before cooking and allow it to operate several minutes after the
cooking is complete to clear all smoke and odors from the
kitchen.
The hood controls are located in front on the underside of the
range hood.
A. Controls
B. Light switch
C. Blower switch
D. Blower speed switch
A
B
C
D
Range Hood Controls
Operating the light
1. Move the light switch to the “1” position to turn range hood
lights ON.
2. Move the light switch to the “0” position to turn range hood
lights OFF.
Operating the blower
1. Move the blower switch to the “1” position to turn the blower
ON. The blower will begin operating at the speed set on the
blower speed switch.
2. Move the blower switch to the “0” position to turn the blower
OFF.
Adjusting the blower
The blower has 3 speed controls. Move the blower speed switch
to “1” position for low speed, “2” position for medium speed or
“3” position for high speed.