4. Check that the front panel is parallel with the cabinet front
when the screen is pushed in. Slide the screen forward.
Tighten the mounting bracket screws so that the range hood
is secured to the cabinet.
5. Align the range hood front panel with the cabinet. Slide the
screen forward. Locate the 2 screws on each side and turn
them counterclockwise to loosen the screws. Adjust the front
of the vent vertically, ³⁄₈" (9.5 mm) up or down, or horizontally,
³⁄₄" (19 mm) front to back, until the front is flush with the
cabinet. Tighten the screws. If it is necessary to adjust the
given dimensions, lower and add or remove the filler strips or
redrill mounting holes.
Electrical Connection
1. Disconnect power.
2. Remove terminal box cover.
3. Remove knockout from top of the terminal box and install a
UL listed or CSA approved ½" strain relief.
4. Determine the location and mount the terminal box to the
inside of the cabinet or wall using the 4 mounting holes in the
back of the terminal box. (The mounting screws are not
supplied.)
5. Pull house power supply cable through the strain relief into
the terminal box.
6. Use UL listed wire connectors and connect black wires (D)
together.
7. Use UL listed wire connectors and connect white wires (A)
together.
8. Connect the green (or bare) ground wire from the home
power supply to the green ground screw inside the range
hood terminal box. Tighten green ground screw.
Use caulking to seal around wire opening.
9. Tighten strain relief screw.
10. Install terminal box cover.
NOTE: Do not turn on power until installation is complete.
Connect the Vent System
Vented Installations
1. Replace the metal filters. See “Range Hood Care” section.
2. Connect the vent system to the range hood vent opening.
Seal the connection with clamps.
3. Reconnect power.
4. Check the operation of the range hood fan and light.
5. Push the range hood screen back in.
A.Mounting bracket screw
B.Flat-blade screwdriver
A.Phillips screwdriver
B.Adjustment screws
A
B
A
B
WARNING
Electrical Shock Hazard
Disconnect power before servicing.
Replace all parts and panels before operating.
Failure to do so can result in death or electrical shock.
A.White wires
B.Green ground screw
C.Ground wire
D.Black wires
E.Wire connectors
E
B
C
D
A
WARNING
Fire Hazard
Electrically ground the blower.
Use copper wire.
Connect ground wire to green ground screw in
terminal box.
Failure to do so can result in death, fire, or
electrical shock.