Kuma Stoves OC-8 Range User Manual


 
0.090> 2.3
roaring,
flickering flame
ideal operating range
0.050> 1.4
0.035> 0.95 weak, sooty flame
0.020> 0.5
____________________________________________________
1 2 3 4 5 6
Position of the carburetor knob
draft in mm water gauge
draft in inches water gauge
SECTION 5
Servicing
ANNUALLY:
*Remove catalyst and fire ring and inspect and clean out burn pot of any build-up or
debris.
*Check flue and clean out soot build-up.
*Clean out stove interior and drip pan.
*Lightly brush off catalyst and inspect for deterioration– replace if necessary.
*Check all gaskets: rope seal around door, window seal (check for loose glass– no need
to remove), access panel gaskets.
*Check oil tank for damage or leaks and clean or replace main tank filter.
*Check all lines and connections for leaks or deterioration.
*A draft reading should be taken for low– and high-fire before operation.
QUARTERLY:
*Turn stove off and allow to cool.
*Remove catalyst and clean out any carbon deposits from burner bottom and oil inlet
inside burner (may need to clean deposits more frequently if using #2 fuel).
7