I
40
MAINTENANCE
Performance
Data
Sheet
Models
Number
5231JA2002A-S
Use
with
replacement cartridge 5231JA2002A
This
system
has
been
tested
according
to
NSF/ANSI
Standards
42
for the
reduction
of the
substances
listed
below.
The
concentration of the indicated
substances
in
water
entering
the system
was
reduced
to a
concentration
less
than
or
equal
to the permissible limit for water
leaving
the system
as
specified
in
NSF/ANSI
42.
System tested
and
certified by
NSF
International against
NSF/ANSI
Standard
42 for
the reduction of
Chlorine Taste
and
Odor and Nominal Particulate
Class
Ill.
Capacity:
500
gal
(1
,892 U
Awrage
Influent
Challenge
Awrage
NSF
'II>
reduction
raq.
Substln:e Influent
Calc:elob
atiou.
Units
apply
Product Watar
Avurage'll>
or
M8x.
permissible
Concerrtration
toeachrvN
Concentration
Recalctian
product 'Miler
concantnotion
Nominal
Particulate
Class
I
Partide
size:
24,333
At
least
10,000
partides/ml
915 96 :!!85%
>0.5to
< 1
um
Chlorine
taste
and
1.9
2.0
mg/1..
± 1
0%
0.07
96.4
:l!50%
odor
Class
Ill
Note that while the testing was performed under
standard
laboratory conditions,
actual
performance
may
vary.
Application Guidelines/Water Supply Parameters
Service Flow
0.5
gpm
(1.89
lpm)
Water Pressure
20
and 120 psi
(140
and
830
kPa)
Water Temperature
36
'F
-100
'F
(0.6 ·c -37.8 'Cl
A WARNING
------....
Do
not
use
with water that
is
microbiologically
unsafe
or
of
unknown
quality
without
adequate
disinfection before or after the system.
•
Systems
must
be
installed
and
operated
in
accordance
with manufacturer's
recommended
procedures
and
guidelines.
Warranty:
See
Warranty
Card
for
Details.
For
a replacement cartridge or for service
contact your
local
dealer.
You
can
also visit our website; www.lg.com
or
call
1-877-714-7488.
Manufactured for
LG®
Electronics
by:
CUNO
lncorporateda
3M
Company 400
Research
Parkway Meriden,
CT
06450 U.S.A.
Telephone:
203-237-5541
Fax:
203-238-8701
~
CAUTION
--------....
To
reduce
the risk
of
property
damage
due
to
water
leakage:
•
Read
and
follow.
Use
instructions before
installation
and
use
of this
system.
•
Install
on
COLD
water
lines
only.
•
Comply
with
all
state
and
local
plumbing
codes.
•
Install
a
pressure
limiting
device
and
water
hammer arrester for
inlet water
pressures
exceeding
80
psi
(552
kPa).
Refer
to
Uniform
Plumbing
Code,
Sections
608.2
and
609.1
0).
•
Never
install or
operate
where inlet water
pressure
may
exceed
125
psi
(862
kPa).
• Protect filter
from
freezing.
Remove
filter
in
temperatures below
33°F
(0.6°C).
•
Replace
cartridge at specified service
interval.
Cartridge
MUST
be
replaced
at
least every
12
months.