LG Electronics LFXS24566S Refrigerator User Manual


 
I
40
MAINTENANCE
Performance
Data
Sheet
Models
Number
5231JA2002A-S
Use
with
replacement cartridge 5231JA2002A
This
system
has
been
tested
according
to
NSF/ANSI
Standards
42
for the
reduction
of the
substances
listed
below.
The
concentration of the indicated
substances
in
water
entering
the system
was
reduced
to a
concentration
less
than
or
equal
to the permissible limit for water
leaving
the system
as
specified
in
NSF/ANSI
42.
System tested
and
certified by
NSF
International against
NSF/ANSI
Standard
42 for
the reduction of
Chlorine Taste
and
Odor and Nominal Particulate
Class
Ill.
Capacity:
500
gal
(1
,892 U
Awrage
Influent
Challenge
Awrage
NSF
'II>
reduction
raq.
Substln:e Influent
Calc:elob
atiou.
Units
apply
Product Watar
Avurage'll>
or
M8x.
permissible
Concerrtration
toeachrvN
Concentration
Recalctian
product 'Miler
concantnotion
Nominal
Particulate
Class
I
Partide
size:
24,333
At
least
10,000
partides/ml
915 96 :!!85%
>0.5to
< 1
um
Chlorine
taste
and
1.9
2.0
mg/1..
± 1
0%
0.07
96.4
:l!50%
odor
Class
Ill
Note that while the testing was performed under
standard
laboratory conditions,
actual
performance
may
vary.
Application Guidelines/Water Supply Parameters
Service Flow
0.5
gpm
(1.89
lpm)
Water Pressure
20
and 120 psi
(140
and
830
kPa)
Water Temperature
36
'F
-100
'F
(0.6 ·c -37.8 'Cl
A WARNING
------....
Do
not
use
with water that
is
microbiologically
unsafe
or
of
unknown
quality
without
adequate
disinfection before or after the system.
Systems
must
be
installed
and
operated
in
accordance
with manufacturer's
recommended
procedures
and
guidelines.
Warranty:
See
Warranty
Card
for
Details.
For
a replacement cartridge or for service
contact your
local
dealer.
You
can
also visit our website; www.lg.com
or
call
1-877-714-7488.
Manufactured for
LG®
Electronics
by:
CUNO
lncorporateda
3M
Company 400
Research
Parkway Meriden,
CT
06450 U.S.A.
Telephone:
203-237-5541
Fax:
203-238-8701
~
CAUTION
--------....
To
reduce
the risk
of
property
damage
due
to
water
leakage:
Read
and
follow.
Use
instructions before
installation
and
use
of this
system.
Install
on
COLD
water
lines
only.
Comply
with
all
state
and
local
plumbing
codes.
Install
a
pressure
limiting
device
and
water
hammer arrester for
inlet water
pressures
exceeding
80
psi
(552
kPa).
Refer
to
Uniform
Plumbing
Code,
Sections
608.2
and
609.1
0).
Never
install or
operate
where inlet water
pressure
may
exceed
125
psi
(862
kPa).
Protect filter
from
freezing.
Remove
filter
in
temperatures below
33°F
(0.6°C).
Replace
cartridge at specified service
interval.
Cartridge
MUST
be
replaced
at
least every
12
months.