Liebherr HC1050 Refrigerator User Manual


 
2
HC 1001 / HC 1050
A delight in freshness
INSTALLATION GUIDELINES
Area Requirements
Verify the following:
Floors can support refrigerator’s weight plus
approximately 1200 pounds (544 kg) of food
weight.
Finish kitchen floor height is level. Kitchen
cabinet that the appliance is installed in must be
shimmed to the floor level if the floor heights are
not equal.
Remove anything attached to the rear or side
walls of appliance that would prevent proper
installation or impede proper ventillation.
Cutout dimensions are accurate.
Electrical outlet is in correct location.
Do not install this refrigerator-freezer next to any
other refrigerator or freezer except another Liebherr
model. Liebherr models are designed to allow
side-by-side installation. They are equipped with
a heating system to eliminate condensation when
refrigerators or freezers are installed side-by-side.
Installing this refrigerator-freezer next to any other
refrigerator or freezer can cause condensation or
cause damage to the Liebherr refrigerator-freezer.
Electrical Requirement
If codes require a separate grounding circuit to be
used, have a qualified electrician install the circuit.
!
WARNING
ELECTRICAL SHOCK HAZARD!
Do not ground to a gas pipe. Check
with a qualified electrician if you
are not sure the appliance is properly
grounded. Do not have a fuse in the
neutral or grounding circuit.
Failure to follow these instructions
could result in death or serious injury
.
!
WARNING
ELECTRICAL SHOCK HAZARD!
• Electrically ground refrigerator.
• Do not use an extension cord.
• Failure to follow these instructions
could result in fire, death or serious
injury.
!
WARNING
ELECTROCUTION HAZARD!
Electrical Grounding Required. This
appliance is equipped with a three-prong
(grounding) polarized plug for your
protection against possible shock hazards.
DO NOT remove the round grounding
prong from the plug.
DO NOT use a two-prong grounding
adapter.
DO NOT use an extension cord to
connect power to the unit.
Failure to follow these instructions could
result in death or serious injury.
Customer’s Responsibility
A 115 Volt, 60 Hz, 15 Amp fused electrical supply is
required. We recommend using a dedicated circuit
for this appliance to prevent electrical overload.
Follow the National Electrical Code and local codes
and ordinances when installing the receptacle.
Venting the Appliance
DO NOT restrict the air flow. Air flow must be
provided for the appliance to operate. The factory
air vents provide 31 square inches (200 cm
2
) of air
flow per appliance. If you are replacing the factory
air vents with an overlay, the air flow must be the
same or greater than the factory air vents.
7082132-02_KIKNv_USA.indd 27082132-02_KIKNv_USA.indd 2 2/28/2005 11:06:27 AM2/28/2005 11:06:27 AM