Impinger I – 1000 Series Ops Manual
4
IMPINGER
®
I AND III CONVEYOR OVENS – MODEL SERIES 1000 AND 1200
UTILITY SPECIFICATIONS REQUIRED – ELECTRIC
Model Energy Power Voltage Current Phase Hz
Recommended Electrical
Specifications
Agency
Listing
***1021-xxx-E Electric 27 kW 400/230 VAC 40 Amps 3 50 Hz
5 Wires, 3 Poles
1N-1G
F-G
1022 Electric 27 kW 120/208 VAC 80 Amps 3 60 Hz
5 Wires, 3 Poles
1N-1G
A-B-F
1023 Electric 27 kW 120/240 VAC 70 Amps 3 60 Hz
5 Wires, 3 Poles
1N-1G
A-B-F
1028 Electric 27 kW
380Y/220
VAC
41 Amps 3 50 Hz
5 Wires, 3 Poles
1N-1G
F
1029 Electric 27 kW 415/240 VAC 38 Amps 3 50 Hz
5 Wires, 3 Poles
1N-1G
F
1032 Electric 27 kW
380Y/220
VAC
41 Amps 3 50 Hz
5 Wires, 3 Poles
1N-1G
F
1202 Electric 27 kW 120/208 VAC 80 Amps 3 60 Hz
5 Wires, 3 Poles
1N-1G
A-B-F
1203 Electric 27 kW 120/240 VAC 70 Amps 3 60 Hz
5 Wires, 3 Poles
1N-1G
A-B-F
1228 Electric 27 kW
380Y/220
VAC
41 Amps 3 50 Hz
5 Wires, 3 Poles
1N-1G
F
1229 Electric 27 kW 415/240 VAC 38 Amps 3 50 Hz
5 Wires, 3 Poles
1N-1G
F
UTILITY SPECIFICATIONS REQUIRED – GAS
Model Energy Power Voltage Current Phase Frequency
Recommended
Electrical
Specification
Gas
Agency
Listing
1030 Nat. Gas 35 kW
220
VAC
1.6 Amps 1 50 Hz
3 Wires, 1 Pole
1N-1G
35 kW/hr at 17.5
mB H
2
O column
F
1031 L.P. Gas 35 kW
220
VAC
1.6 Amps 1 50 Hz
3 Wires, 1 Pole
1N–1G
35 kW/hr at 27.5
mB H
2
O column
F
***1033-xxx-E Nat. Gas 35 kW
230
VAC
3 Amps 1 50 Hz
3 Wires, 1 Pole
1N-1G
35 kW/hr at 17.5
mB H
2
O column
F-G
***1034-xxx-E L.P. Gas 35 kW
230
VAC
3 Amps 1 50 Hz
3 Wires, 1 Pole
1N-1G
35 kW/hr at 27.5
mB H
2
O column
F-G
1040 Nat. Gas
120,000
BTU
120/230
VAC
5 Amps 1 60 Hz
4 Wires, 1 Pole
1N-1G
120,000 BTU at 7
inches H
2
O column
A-F
1041 L.P. Gas
120,000
BTU
120/230
VAC
5 Amps 1 60 Hz
4 Wires, 1 Pole
1N-1G
120,000 BTU at 11
inches H
2
O column
A-F
1042 Nat. Gas
120,000
BTU
230
VAC
5 Amps 1 50 Hz
3 Wires, 1 Pole
1N-1G
120,000 BTU at 7
inches H
2
O column
F
1043 L.P. Gas
120,000
BTU
230
VAC
5 Amps 1 50 Hz
3 Wires, 1 Pole
1N-1G
120,000 BTU at 11
inches H
2
O column
F
1046 Nat. Gas 126 MJ
240
VAC
5 Amps 1 50 Hz
3 Wires, 1 Pole
1N-1G
126 MJ/hr at 1.75
kPa H
2
O column
E-F
1047 L.P. Gas 126 MJ
240
VAC
5 Amps 1 50 Hz
3 Wires, 1 Pole
1N-1G
126 MJ/hr at 1.75
kPa H
2
O column
E-F
1240 Nat. Gas
120,000
BTU
120/230
VAC
5 Amps 1 60 Hz
4 Wires, 1 Pole
1N-1G
120,000 BTU at 7
inches H
2
O column
A-F
1241 L.P. Gas
120,000
BTU
120/230
VAC
5 Amps 1 60 Hz
4 Wires, 1 Pole
1N-1G
120,000 BTU at 11
inches H
2
O column
A-F
1242 Nat. Gas
120,000
BTU
230
VAC
5 Amps 1 50 Hz
3 Wires, 1 Pole
1N-1G
120,000 BTU at 7
inches H
2
O column
F
1243 L.P. Gas
120,000
BTU
230
VAC
5 Amps 1 50 Hz
3 Wires, 1 Pole
1N-1G
120,000 BTU at 11
inches H
2
O column
F
NOTE: All ovens require separate service and dedicated neutral.