Lincoln 3270-2 Convection Oven User Manual


 
Impinger X2 – Digital Service Manual – Dom & Int’l
30
!! CAUTION !!
Please note that a model number change associated with the Baldor Main Fan Motor has been instituted. This
change in motor model number also requires a change in the type of fan belt being used. Therefore, when
replacing a fan belt it is important to note which type of motor is being used.
Use the following fan belt … when using this main fan motor…
Motor, main fan, 3HP, 1 Phase (60 Hz Model Only) Vendor-35V087T356G1
Motor, main fan, 3HP, 3 Phase (60 Hz Model Only) Vendor-35V426T676G1
Motor, main fan, 3HP, 1 Phase (50 Hz Model Only) Vendor-35V424Q013G1
Gates 6929 (V-Belt, 21/32” x 29”)
Lincoln Part # 390128
Motor, main fan, 3HP, 3 Phase (50 Hz Model Only) Vendor-35V426Y886G1
Baldor Motor P/N M3161TA – Lincoln Production #4060274
Gates 6931 (V-Belt, 21/32” x 31”)
Lincoln Part # 508202EP
Baldor Motor P/N 35S270T356 – Lincoln Production #4060276
This motor requires the
following fan belt:
Lincoln Part # 508202EP
Dimensions: 21/32” x 31”
This motor requires the
following fan belt:
Lincoln Part # 390128
Dimensions: 21/32” x 29”
This motor requires the
following fan belt:
Lincoln Part # 390128
Dimensions: 21/32” x 29”
Baldor Motors:
M3161TA
35S270T356
Baldor Motors:
35V424Q013G1
35V087T356G1
Baldor Motors:
35V426T676G1
35V426Y886G1