Manitowoc Ice Q 1800 Ice Maker User Manual


 
11
Electrical System
Component Specifications and Diagnostics
MAIN FUSE BIN SWITCH
Function Function
The control board fuse stops ice machine operation
if electrical components fail causing high amp
draw.
Bin switch operation is controlled by movement of
the water curtain. The bin switch has two main
functions:
1. Terminating the harvest cycle and returning the
ice machine to the freeze cycle.
Specifications
The main fuse is 250 Volt, 7 amp.
This occurs when the bin switch is opened and
closed again within 7 seconds during the harvest
cycle.
Check Procedure
WARNING
High (line) voltage is applied to the control board
(terminals #55 and #56) at all times. Removing
the control board fuse or moving the toggle
switch to OFF will not remove the power
supplied to the control board.
2. Automatic ice machine shut-off.
If the storage bin is full at the end of a harvest
cycle, the sheet of cubes fails to clear the water
curtain and holds it open. After the water curtain
is held open for 7 seconds, the ice machine
shuts off.
1. If the bin switch light is on with the water
curtain closed, the fuse is good.
The ice machine remains off until enough ice is
removed from the storage bin to allow the sheet
of cubes to drop clear of the water curtain. As
the water curtain swings back to the operating
position, the bin switch closes and the ice
machine restarts.
WARNING
Disconnect electrical power to the entire ice
machine before proceeding.
2. Remove the fuse. Check the resistance across
the fuse with an ohm meter.
Important
Reading Result
The water curtain must be ON (bin switch closed)
to start ice making.
Open (OL) Replace fuse
Specifications
Closed (O) Fuse is good
The bin switch is a magnetically operated reed
switch. The magnet is attached to the lower right
corner of the water curtain. The switch is attached
to the evaporator mounting bracket.
The bin switch is connected to a varying D.C.
voltage circuit. (Voltage does not remain constant.)
NOTE: Because of a wide variation in D.C. voltage,
it is not recommended that a voltmeter be used to
check bin switch operation.