Manitowoc Ice Q 1800 Ice Maker User Manual


 
3
Electrical System
Initial Start-Up Or Start-Up After
Automatic Shut-Off (cont.)
2. REFRIGERATION SYSTEM
START-UP
The compressor starts after the 45-
second water purge, and it remains on
throughout the Freeze and Harvest
cycles.
The water fill valve is energized at the
same time as the compressor. It
remains on until the water level sensor
closes for 3 continuous seconds.
The hot gas valve(s) remains on for
the first 5 seconds of the initial
compressor start-up.
*OVERLOAD
FAN CYCLE CONTROL
BIN SWITCH
TB35
TB33
(52)
(51)
(48)
CONTACTOR
CONTACTS
L1
(42)
(66)
(64)
ICE THICKNESS PROBE
WATER LEVEL PROBE
NOT USED
TB35
HIGH PRES
CUTOUT
TB32
L1
(55)
SV1646-2
RUN CAPACITOR
RUN CAPACITOR**
C
S
R
TB34
(53)
(47)
(85) (86)
COMPRESSOR
FAN MOTOR
(AIR COOLED ONLY)
R
R
(45)
(46) (50)
PTCR
BIN SWITCH LIGHT
HARVEST LIGHT/
SAFETY LIMIT CODE LIGHT
CLEAN LIGHT
WATER LEVEL
(49)
(63)
(62)
(66)
(65)
(69)
ICE
OFF
CLEAN
(67)
(68)
1F
1C
LOW D.C.
VOLTAGE
PLUG
(62)
1G
TOGGLE SWITCH
68
67
69
66
62
VIEW FOR WIRING
INTERNAL WORKING
VIEW
TB37
(74)
(59)
(73)
(56)
CONTACTOR
COIL
TERMINATES AT
PIN CONNECTION
TB30
T
B30
TB30
TB30
L2 (N)
SEE SERIAL PLATE FOR VOLTAGE
(58)
FUSE (7A)
TRANS.
2
4
1
3
5
(61)
(60)
TB31
(76)
(98)
(57)
(99)
(75)
SOLENOID
DUMP
SOLENOID
(81)
WATER
PUMP
(77)
(80)
HOT GAS
(21)
(22)
WATER
VALVE
TB30
TB30
Self-Contained Models
2. Refrigeration System Start-Up (5 Seconds)
Toggle Switch
ICE
Bin Switch
Closed
Control Board Relays
#1 Water Pump Open / OFF
#2 Water Fill Valve Closed / ON
#3 Hot Gas Solenoid Closed / ON
#4 Water Dump Valve Open / OFF
#5 Contactor Coil Closed / ON
Compressor ON
Safety Controls (Which could stop ice machine operation)
High Pressure Cut-Out Closed
Main Fuse (On Control Board) Closed