Manitowoc Ice Q 1800 Ice Maker User Manual


 
40
Refrigeration System
Freeze Cycle Suction Pressure High Checklist
Possible Cause Check/Correct
Improper installation See “Installation/Visual Inspection Checklist”
Discharge pressure Discharge pressure is too high, and is affecting low side (See “Freeze
Cycle Discharge Pressure High Checklist”)
Improper refrigerant charge Overcharged
Wrong type of refrigerant
Other Non-Manitowoc components in system
Hot gas valve stuck open
TXV flooding (check bulb mounting)
Defective compressor
Freeze Cycle Suction Pressure Low Checklist
Possible Cause Check/Correct
Improper installation See “Installation/Visual Inspection Checklist”
Discharge pressure Discharge pressure is too low, and is affecting low side (See “Freeze
Cycle Discharge Pressure Low Checklist”)
Improper refrigerant charge Undercharged
Wrong type of refrigerant
Other Non-Manitowoc components in system
Improper water supply over evaporator (See “Water System Checklist”)
Loss of heat transfer from tubing on back side of evaporator
Restricted/plugged liquid line drier
Restricted/plugged tubing in suction side of refrigeration system
TXV starving
NOTE: Do not limit your diagnosis to only the items listed in the checklists.