Manitowoc Ice QF2200 Ice Maker User Manual


 
Section 2 Installation Instructions
Part No. 80-1214-3 2-5
Electrical Service
GENERAL
VOLTAGE
The maximum allowable voltage variation is ±10% of the
rated voltage on the ice machine model/serial number
plate at start-up (when the electrical load is highest).
FUSE/CIRCUIT BREAKER
A separate fuse/circuit breaker must be provided for
each ice machine. Circuit breakers must be H.A.C.R.
rated (does not apply in Canada).
QF400 115/60/1 ice machines are factory pre-wired
with a power cord and 5-15P plug confirmation.
QF400 230/50/1 ice machines are factory pre-wired
with a power cord, no plug is supplied.
QF2200/QF2300 with Remote Condensing Unit the
ice machine head section and remote condensing unit
are wired independent of each other. A separate
dedicated fuse/circuit breaker must be provided
for each
section. Circuit breakers must be H.A.C.R. rated (does
not apply in Canada).
MINIMUM CIRCUIT AMPACITY
QC700/QF800/QF2200/QF2300 Only
The minimum circuit ampacity is used to help select the
wire size of the electrical supply. (Minimum circuit
ampacity is not the ice machine’s running amp load.)
The wire size (or gauge) is also dependent upon
location, materials used, length of run, etc., so it must be
determined by a qualified electrician.
!
Warning
All wiring must conform to local, state and national
codes.
!
Warning
The ice machine must be grounded in accordance
with national and local electrical codes.