Miele 09 730 840 Ventilation Hood User Manual


 
a Extension piece
b Tower
c Canopy
d Controls
e Grease filters
f Recirculation grille
(only for recirculation mode)
g Hob lighting
h Charcoal filter
(special accessory for recirculation
mode)
i Sensor for switching the fan on
and off
j Sensor for the hob lighting
k Sensors for selecting the fan
power level
l Sensor for the run-on option
This sensor activates the run-on option.
The fan can be set to switch off
automatically after either 5 or 15
minutes.
m Sensor for the grease filters
The sensor lights up when the grease
filters need to be cleaned.
It is used to reset the operating hours
counter every time the grease filters are
cleaned (see "Cleaning and care").
It can also be used to check and alter
the operating hours counter.
n Sensor for the charcoal filters
The sensor for the charcoal filter lights
up when the charcoal filter used in
recirculation mode needs to be
replaced. For this to happen, the
operating hours counter needs to be
activated before the appliance is used
for the first time.
The sensor is used to reset the
operating hours counter every time the
charcoal filters are replaced (see
"Cleaning and care").
It can also be used to check and alter
the operating hours counter.
For information about using the
appliance, see "Operation".
Guide to the appliance