Miele 09 730 840 Ventilation Hood User Manual


 
a Extraction
b Recirculation
c Ventilation grill positioned at the top
for recirculation
d, e
The shaded areas represent the wall or
ceiling area for the vent cut-out and for
fitting the connection socket.
For recirculation mode, you only require
cut-out area d and a connection
socket.
Connection for air extraction
C 150 mm, or C 125 mm with reducing
collar.
Safety distance between hob and
cooker hood (S)
The following minimum safety
distance must be maintained
between the top of the cooker/hob
and the bottom of the cooker hood
unless a greater distance is
specified by the manufacturer of the
cooker or hob:
Cooking appliance Distance
S
Electric hob 450 mm
Open Grill 650 mm
Deep fat fryer (electric) 650 mm
Multi-burner gas hob with
a maximum total output of
12.6 kW, no burner
exceeding 4.5 kW.
650 mm
Multi-burner gas hob with
a total output of more than
12.6 kW, or a multi-burner
gas hob where one burner
exceeds 4.5 kW.
760 mm
Single gas burner with a
maximum output of 6 kW.
650 mm
Single gas burner with
output exceeding 6 kW.
760 mm
See "Warning and Safety"
instructions for further information.
Appliance dimensions
31