Miele DA 219-2 EXT Ventilation Hood User Manual


 
Safety regulations prohibit the fitting
of this cooker hood over a solid fuel
stove.
For safety reasons a minimum safe
distance must be maintained be-
tween the top of the hob / cooker
and the bottom of the cooker hood:
450 mm above electric hobs /
cookers
650 mm above gas hobs / cookers
650 mm above an open grill
from our range.
See "Warning and Safety instructions"
for further information.
A distance of 650 mm may be prefer-
able above electric hobs / cookers to
give more working space.
When deciding dimension S ensure
that the minimum specified safety dis-
tance between the hob / cooker and
the cooker hood is maintained. If the
hood is fitted flush to the ceiling make
sure that the remaining distance to the
ceiling is not greater or less than ap-
pliance height H.
Appliance height H:
DA 216-2
Extraction and EXT . . . . . 700* -940 mm
Recirculation . . . . . . . . . 790 -1025 mm
DA 217-2
Extraction . . . . . . . . . . . . 710* -950 mm
Recirculation . . . . . . . . . 800 -1035 mm
DA 219-2
Extraction and EXT . . . . . 730* -970 mm
Recirculation . . . . . . . . . 820 - 1055 mm
* With air extraction to the rear through
a wall the total height must be at least
790 mm.
To fit the tower, distance A between
the top of the tower and the ceiling
must be at least 20 mm.
The shaded area represents the
wall or ceiling area for the vent cut-
out, for feeding the connection cable
through to an external fan and for fitting
the connection socket.
(For recirculation mode the connection
socket may only be fitted in a wall area).
Connection for air extraction
ø 150 mm or ø 125 mm with reducing
collar.
Appliance dimensions
21