Miele DA 219-2 EXT Ventilation Hood User Manual


 
Control unit
(only when operating with an external
fan)
Fit the exhaust socket supplied into the
canopy. It has an integrated non-return
flap.
If a 150 mm ø exhaust ducting is
being used, adapt the connection by
cutting it off at the join with a sharp
knife (see illustration).
The exhaust connection does not
need adapting if 125 mm ø ducting
is being used.
Secure the exhaust connection to
the canopy with four 2 x 13 mm
screws.
On EXT model cooker hoods the con-
trol unit is fitted instead of the motor
unit and then secured with self lock-
ing nuts.
Electrical connection
Connect the canopy connection
cable to the corresponding coup-
lings on the left and right of the
motor unit or control unit.
Do this by connecting the four pole
plug into the rear connection of the
coupling on the left of the motor unit
or control unit.
Connect the six pole plug into the
coupling on the right of the motor
unit or control unit.
Secure the cable with the cable
holders as illustrated (this does not
apply to EXT models).
Installation
28