Miele DA 219-2 EXT Ventilation Hood User Manual


 
Retaining plates
There are three retaining plates A, B
and C for fixing the cooker hood to the
wall.
First of all drill the holes for attaching
the canopy and for fitting retaining
plate A.
Before fitting the retaining plate draw
a vertical line centrally above the
hob on the back wall.
Mark measurement S from the hob
surface upwards (see "Appliance
dimensions"). This marks the height
of the lower rim of the cooker hood.
DA 216-2 / EXT, 217-2:
Drill an 8 mm ø hole on the middle
line 18 mm above the height marked
S. Insert an S8 plug into the hole.
DA 219-2 / EXT:
Drill two 8 mm ø holes, 18 mm above
the height marked S and 250 mm
right and left of centre. Insert S8
plugs.
Retaining plate A
Drill two 8 mm ø holes, one at S +
100 mm and one at S + 425 mm on
the centre line for the retaining plate
(see "Appliance dimensions"). Insert
S8 plugs.
Installation
24