Miele DA 219-2 EXT Ventilation Hood User Manual


 
Recirculation
If site conditions are not suitable for the
cooker hood to be used for air extrac-
tion the appliance must be connected
for recirculation.
Push the directional unit on to the
top retaining plate.
Secure the flexible hose supplied to
the directional unit and to the reduc-
ing collar on the motor unit using
hose clips.
Insert the recirculation active char-
coal filters (see section "Cleaning
and care").
The recirculation active charcoal fil-
ters necessary for recirculation are
available from the Spare Parts De-
partment or your dealer.
Extension piece
An extension piece allows the cooker
hood to be fitted at varying distances
from the ceiling (see section appliance
dimensions).
The extension piece has openings at
each side. These are needed for venti-
lation when the appliance is being
used in recirculation mode.
Recirculation Extraction
For recirculation the extension piece is
fitted with the openings at the top.
For air extraction the openings are not
required. In this case the extension
piece is fitted with the openings at the
bottom. They are then covered by the
tower.
Installation
30