INSTALLATION
INSTALLATION (CONT.)
Plumbing Connections
NOTE:
Plumbing connections must comply with all applicable sanitary and plumbing codes.
Water Connections
1. All M-DH dishwashers require a single, hot water supply.
2. The hot water connection to the dishwasher is 1/2” BSP male.
3. The connection is made from underneath the dishwasher.
4. The recommended minimum water temperature is 140F/60°C.
5. A manual shut-off valve for water (supplied by others) should be installed in the supply
line to allow for servicing of the machine. The shut-off valve should be the same size or
larger than the supply line.
6. Install a pressure reducing valve (PRV) in the water supply line if flow pressure exceeds
20-22 PSI/138-151.8kPa.
Drain Connections
1. The dishwasher is a gravity drain machine equipped with 1-1/2” O.D. hose connection
point.
2. The maximum drain flow rate is 15 gallons/min-56.8 liters/min.
3. Drain height for the dishwasher must not exceed 11” (280mm) above the floor level.
4. The drain connection is made to the dishwasher from behind the machine or through an
access hole in the base of the machine.
Ventilation
NOTE:
Ventilation must comply with local sanitary and plumbing codes.
CAUTION:
Exhaust air should not be vented into a wall, ceiling, or concealed space of a building.
Condensation can cause damage.