Lifebreath RNC120D Ventilation Hood User Manual


 
Ventilation Dehumidistat
PART NO. 99-116
The High/Low Speed
Switch initiates High or
Low speed ventilation.
This control also has an
ON/OFF Switch and a
Dehumidistat Dial.
20/40 ON/OFF
Dehumidistat
PART NO. 99-2040
The 20/40 Switch will toggle
from continuous low speed
ventilation to an intermittent
mode of 20 minutes fan ON (in
low speed) and 40 minutes fan
OFF. The Dehumidistat Dial will
initiate High Speed ventilation
when the indoor humidity level
exceeds the set point (regardless
position of the 20/40 Switch.).
This control also has an ON/OFF
Switch.
Recirculation Control
PART NO. 99-RECIRC
The Recirculation Switch will
toggle from continuous low
speed ventilation to
recirculation mode (closes the
fresh air damper and
circulates the building air).
The Dehumidistat Dial will
initiate High Speed
ventilation when the indoor
humidity level exceeds the set
point (regardless position of
the RECIRC Switch.). This
control also has an ON/OFF
Switch and a Dehumidistat
Dial.
Remote Dehumidistat
PART NO. 99-130 W
hite
The Remote Dehumidistat
activates high speed ventilation
when the indoor humidity level
exceeds the set point.
12
20 Minute Timer
PART NO. 99-132
Crank Timer
PART NO. 99-101
Off
10
20
30
40
50
60
Remote Control Devices
Touch Pad
The Touch Pad initiates high
speed operation.
20 Minute Status Lights
The 20 Minute Status Light indicates
high speed operation is activated.
Crank Dial
Rotate the dial for up to 60
minutes high speed operation.
DEHUMIDISTAT
Optional Main Control Features
The amount of ventilation required in your home will fluctuate
according to the activity level in the house. Higher activity levels
require more ventilation.
Main controls can be mounted in a central location of the home (i.e.
beside the furnace thermostat) which will provide the user with
complete control over their ventilation system from a convenient
location.
The ON/OFF Switch
The ON/OFF Switch will turn the HRV ON or OFF. Controls with an
ON/OFF switch can be modified to ON/Standby by adjusting the circuit
board DIP Switches (Refer to "Mode DIP Switch Settings").
The Dehumidstat
Main controls feature a dehumidistat which is used to reduce high
indoor humidity levels during the heating season. The control has a
selector knob with setpoints ranging from 20% to 80% relative
humidity (RH). Most people are comfortable when indoor relative
humidity levels are in a range from 30% to 45%.
The dehumidistat switches the HRV to high speed ventilation when the
moisture level in the home exceeds the desired setpoint. The
dehumidistat should only be used during the heating season. It must be
set to the OFF position throughout the rest of the year.
Dehumidistat
Dial
High/Low
Speed Switch
ON/OFF
Switch
Dehumidistat
Dial
Recirculation
Switch
ON/OFF
Switch
Dehumidistat
Dial
Optional Timers
Install timers at each exhaust location of your system.
Dehumidistat
Dial
20/40 Switch
ON/OFF
Switch
• Connects to RED, BLACK and GREEN (LED drive) terminals.
• Use a minimum of three 20 gauge low voltage wires.
• Connect up to 4 on 100 ft (91 m) wire max.
• Mounts in a 2 x 4 box.
• Initiates high speed ventilation for up to 60 minutes.
• Requires 2 lead low voltage (20 gauge) wire.
• Mounts in a 2" x 4" box.