Lifebreath RNC120D Ventilation Hood User Manual


 
32
Troubleshooting
Poor Air Flow
Supply air feels cold
Dehumidistat is not Operating
Humidity Levels are too High in Winter
Condensation is appearing on the
windows
Humidity Levels are too Low
HRV and / or Ducts Frosting up
Condensation or Ice Build Up in
Insulated Duct to the Outside
Water in the bottom of the HRV
20 Minute Timer Not Working
1/4(6mm) mesh on the outside hoods is plugged
filters plugged
core obstructed
house grilles closed or blocked
dampers are closed if installed
poor power supply at site
duct is restricting HRV
improper speed control setting
HRV air flow improperly balanced
poor location of supply grilles, the air flow may irritate
the occupant
outdoor temperature extremely cold
improper connection to ventilator
external low voltage is shortened out by a staple or nail
check dehumidistat setting it may be on OFF
dehumidistat is set too high
.lifestyle of the occupants
moisture coming into the home from an unvented or
unheated crawl space
moisture is remaining in the washroom/bathroom and
kitchen areas
condensation seems to form in the spring and fall
HRV is set at too low a speed
dehumidistat control set too low
blower speed of HRV is too high
lifestyle of occupants
HRV air flow may be improperly balanced
HRV
air flow is improperly balanced
malfunction of the HRV defrost system
incomplete vapor barrier around insulated duct
a hole or tear in outer duct covering
drain pans plugged
improper connection of HRV drain lines
HRV is not level
drain lines are obstructed
HRV heat exchange core is not properly installed
Wiring
Faulty control
Faulty circuit board
clean exterior hoods or vents
remove and clean filter
remove and clean core
check and open grilles
open and adjust dampers
have electrician check supply voltage at house
check duct installation
increase the speed of the HRV
have contractor balance HRV
locate the grilles high on the walls or under the baseboards,
install ceiling mounted diffuser or grilles so as not to directly
spill the supply air on the occupant (eg. over a sofa)
turn down the HRV supply speed. A small duct heater (1kw)
could be used to temper the supply air
placement of furniture or closed doors is restricting the
movement of air in the home
if supply air is ducted into air handler return, the air handler fan
may need to run continuously to distribute ventilation air
comfortably
check that the correct terminals have been used
check external wiring for a short
set the dehumidistat at the desired setting
set dehumidistat lower
avoid hanging clothes to dry, storing wood and venting clothes
dryer inside. Heating wood may have to be moved outside
vent crawl space and place a vapor barrier on the floor of the
crawl space
ducts from the washroom/bathroom should be sized to remove
moist air as effectively as possible, use of a
washroom/bathroom fan for short periods will remove
additional moisture
timer or fan can be added to washroom/bathroom exhaust
on humid days, as the seasons change, some condensation
may appear but the homes air quality will remain high with
some HRV use
increase speed of the
HRV
set dehumidistat higher
decrease HRV blower speed
humidity may have to be added through the use of humidifiers
have a contractor balance HRV air flow
Note: minimal frost build-up is expected on cores before
unit initiates defrost cycle functions
have HVAC contractor balance the HRV
ensure working properly.
tape and seal all joints
tape any holes or tears made in the outer duct covering
ensure that the vapor barrier is completely sealed
ensure O-Ring on drain nozzle sits properly
look for kinks in line
check water drain connections
make sure water drains properly from pan
disconnect external controls and
run unit through self test. If
the unit runs through self test successfully, then the circuit
board is okay.
check wiring connection.
make sure wires are connected to proper terminals.
test 20 Minute Timer, press and hold the button for 10 seconds
then release. The unit should run on high speed and then return
to normal operation when the button is released.
Symptom Cause Solution