Pitco Frialator 60149517 Ventilation Hood User Manual


 
Solstice I12+ Cooking Computer for ROV Fryers
Pitco P/N 60149517 & 60149518
Page 23 of 44 L22-378 Rev 3
8 To Enter Programming Level 3 (for the Technician):
With no cook timers running, displays will show one of the following displays:
, , or .
Press the key. The left display will show . The right display will
be blank.
Enter password
Level 3 Password
using the product keys as a numeric keypad for entry.
Display will show . Product key indicators will illuminate
to prompt operator to select a key. This section details parameters that
may be changed in Level 3 programming.
8.1 Offset the Temperature Display:
This adjustment allows the displayed temperature value to be offset to reflect the true center vat
temperature while reading the probe tip temperature. Default value is zero. With zero value set,
displayed values are the probe temperature.
With display showing press product key 1.
Display shows [OFF nn F] [DEGREES], where “nn” is the value of the adjustment.
Negative values are preceded with a minus sign.
To change this value, use the product keys for numeric entry of a new value.
Press the
key. Display will show [POSITIVE] [DEGREES].
Use the product key [0] to scroll choices (Positive or Negative value). After
selection, press the key. Display returns to .
8.2 Melt Cycle ON Time:
With display showing press product key 2.
Display shows [MLTON :nn] [MELT ON], where “nn” is the value, in seconds, of
time for a melt cycle heat pulse.
To change this value, use the product keys for numeric entry of a new value.
Press the key. Display returns to .
8.3 Minimum ON and OFF Cycle Time:
With display showing press product key 3.
Display shows [MIN ON:nn] [MIN ON], where “nn” is the value, in seconds, of time for
minimum heat pulse period.
To change this value, use the product keys for numeric entry of a new value, then press
the key to save. Display shows [MIN OFF:nn] [MIN OFF], where “nn” is the value, in
seconds, of time for minimum heat off period. Use the product keys for numeric entry of a new
value.Press the key. Display now shows .