8.8.8 Factory Reset:
Factory Reset provides a quick way to erase all setup changes and restore control to
factory settings.
Warning: Any settings made prior to a factory reset will be lost. This includes
customer specific downloads performed at Pitco Frialator. Heat profile after a reset
is ROV2 for electric appliances.
With the display showing , press 8 product key. The operator
will be prompted to confirm the factory reset, press the YES [6] key to continue. After a few
moments, the display will show [ P ]. Press the display will return to
.
8.8.9 Standing Pilot Toggle:
For some applications, it is desirable to maintain the gas pilot flame when the appliance is
OFF. Heat from the pilot keeps solid shortening in the liquid state for quicker warm-ups in the
morning. Default setting for standing pilot is off.
Note: Heat Demand Profile (section 4.8.3) must be set to Generic 1, or T-stat.
Standing Pilot toggle has no effect in with any other setting.
With the display showing , press product key 9. Display will
show [STANDING] [PILOT n], where “n” is ON or OFF. Use product key [0] change value, then
press the to save choice. Display returns to .
8.8.10 Flex Time Toggle:
With display showing , press product key [0].
Display will show [FLEXTIME][xxx]. Where “xxx” is ON, OFF, SHRINK, or STRETCH.
o “ON” – Both shrink time and stretch time are active.
o “OFF” Both shrink time and stretch time are inactive.
o “SHRINK” – Only shrink time is active, cook times only shorten from setting.
o “STRETCH” – Only stretch time is active, cook times only lengthen from setting.
Use product key [0] change value, then press the to save choice.
Display returns to .
8.8.11 Exit More Service sub menu:
With display showing , press key.
Display will show . Continue with Level 3 programming in this section (display
showing [SERVICE]), or continue.